The Scope
Cube Offshore was engaged by Quadrant Energy to undertake a structural assessment of the Chervil monopod. The focus of the assessment was the structural integrity of the primary structure for extreme environmental loading.
The Outcome
This assessment demonstrated the structural capacity using the structural strength requirements of the code API RP2A 21st Edition. API RP2A 17th edition (1986) was used for the original design.